Edit ports window – HP XP P9500 Storage User Manual

Page 328

Advertising
background image

Edit Ports window

Description

Item

Attribute of the port indicating I/O flow.

Port Attribute

Initiator: Issues I/O commands to a target port when I/O is executed
between storage systems with Continuous Access Synchronous, and so
on.

Target: Receives I/O commands from a host.

RCU Target: Receives I/O commands from an initiator when I/O is
executed between storage systems with Continuous Access Synchronous,
and so on.

External: Issues I/O commands to a target port of an external storage
system with External Storage.

Select whether LUN security is enabled or disabled.

Port Security

Select the data transfer speed, in Gbps, for the selected fibre channel port.

Port Speed

If Auto is selected, the storage system automatically sets the data transfer
speed to 1, 2, 4, 8, or 10 Gbps.

Caution: If you are using 2-Gbps HBA and switch, set the transfer speed of
the CHF (fibre channel adapter) port as 2 Gbps. If you are using 1-Gbps
HBA and switch, set the transfer speed of the CHF port as 1 Gbps. If you
are using 4-Gbps HBA and switch, set the transfer speed of the CHF port
as 4 Gbps. If you are using 8-Gbps HBA and switch, set the transfer speed
of the CHF port as 8 Gbps. However, the transfer speed of the CHF port
cannot be set as 1 Gbps when the CHF is 8US. Therefore, 1-Gbps HBA
and switch cannot be connected. If the Auto Negotiation setting is required,
the linkup may become improper at server restart. Check a channel lamp,
and if it is blinking, remove and re-insert the cable to perform the signal
synchronization and linkup.

When the transfer speed of the CHF port is set to Auto, the data might not
be transferred at the maximum speed depending on the connected device.
Confirm the transfer speed appearing in Speed in the Ports list when you
start up the storage system, HBA, or switch. When the transfer speed is not
the maximum speed, select the maximum speed from the list on the right or
remove and reinsert the cable.

Only 10 Gbps can be specified for the FCoE port. Auto cannot be specified
for the FCoE port.

328 LUN Manager GUI reference