With Fibre Channel connections, you can use the switches as ordinary switch connections. No
special settings are required for the HP XP P9500.

Direct connections up to 10 km with single-mode longwave Fibre Channel interface cables are
supported. Link speed determines the maximum distance you can transfer data and still achieve
good performance. The following table shows maximum distances at which performance is
maintained per link speed, over single-mode longwave Fibre Channel.

Distance maximum performance maintained

Link speed

10 km

1 Gbps

6 km

2 Gbps

3 km

4 Gbps

3 km

8 Gbps

Your HP account team can provide the latest information about the availability of serial-channel
Continuous Access Synchronous connections.

Supported data path configurations

Three Fibre Channel configurations are supported for Continuous Access Synchronous:

“Direct connection” (page 34)

“Switch connection” (page 34)

“Extender connection” (page 35)