5 configuration operations, Configuration workflow, Defining port attributes – HP XP P9500 Storage User Manual

Page 47: Configuration workflow defining port attributes

Advertising
background image

5 Configuration operations

This chapter provides instructions for configuring Continuous Access Synchronous.

Configuration workflow

Configuration consists of the following tasks:

Check prerequisites for each procedure.

See

“Planning for pairs and pair volumes” (page 19)

.

On the primary and secondary systems, install the data paths. See

Data path requirements

and configurations (page 33)

.

On primary and secondary system, configure the initiator and RCU target ports Fibre Channel
ports that will be used for Continuous Access Synchronous operations. See

“Ports” (page 36)

and

“Defining port attributes” (page 47)

for details.

On the primary system, create the Continuous Access Synchronous association with the
secondary system. See

“Configuring storage systems, defining logical paths” (page 48)

.

Logical paths between the systems are added during this procedure.

You may also perform these additional procedures prior to the initial copy:

Add additional logical paths. See

Configuring additional logical paths (page 52)

.

Specify the number of volumes to copy at one time. See

Setting number of VOLs. copied

concurrently, other options (page 53)

.

Defining port attributes

Initiator and RCU target ports must be set up on the primary and secondary system for Continuous
Access Synchronous command and data transfer.

Prerequisite information

Before configuring ports, make sure they are ready to have a new attribute assigned, as follows:

If you are changing a target port to an initiator port, prepare the port for the change as follows:

Confirm that the port is offline.

Disconnect the port from the host.

Remove all channel paths to the port.

If you are changing an initiator port to target or RCU target port, prepare the port for the
change as follows:

Release all pairs using the ports.

Delete the paths from the initiator port to the remote storage system.

Delete the RCU.

The number of hosts connected to a target port must be limited to 128 or fewer to avoid
disconnection. See

Ports (page 36)

for information about target, initiator, and RCU target ports.

Procedure 7 To define port attributes

1.

In Remote Web Console, click Actions > Remote Copy > Continuous Access Synchronous >
RCU Operation.

2.

Change to Modify mode by clicking the

icon.

Configuration workflow

47