Where:

*

is the instance number.

HOST

is the host name.

Example:

Error codes appear on the right of the equal symbol (=).

Review RAID Manager error codes in the following topics.

“RAID Manager SSB2 error codes when SSB1 = 2E31/B901/B90A/B90B/B912/D004”
(page 79)

“SSB2=B992 error codes when SSB1 = B901 or B90A” (page 87)

RAID Manager SSB2 error codes when SSB1 =
2E31/B901/B90A/B90B/B912/D004

Description

Error code

(SSB2)

The pair cannot be created because the specified P-VOL belongs to a different CLPR than the registered
consistency group CLPR.

4A96

A pair cannot be resynchronized because the specified consistency group does not have the Open/MF
attribute.

4B02

The command cannot be executed because the user authentication is not performed.

9100

A request for a Paircreate or Pairresync operation to the consistency group was rejected because supported
and unsupported microcodes are used in the DKC.

B923

You cannot run the following operations to a pair in a 2DC configuration:

B927

Swap Suspend

Takeover

The pair cannot be created because the Mirror ID is invalid.

B928

The pair operation was rejected because the online microcode is being replaced.

B929

The pair cannot be created because the specified volume is a command device.

B92A

The pair cannot be created because Cnt Ac-S is not installed.

B934

S-VOL hide mode is not supported.

B935

The specified volume is a P-VOL. The pair cannot be released because the P-VOL is specified as an S-VOL.

B93B

The specified volume is an S-VOL. The pair cannot be released because the S-VOL is specified as an P-VOL.

B941

The command was rejected because the volume status is SMPL.

B945

The specified LU is not defined. The DKC configuration might have been changed. Restart RAID Manager.

B952

The operation cannot run because pair status is PSUS, PSUE, or PDUB.

B97B

The command was rejected because the volume status is SMPL.

B97C

The pair cannot be created because the consistency group number is greater than is allowed.

B990

If this error occurred when you did not specify the consistency group number, Contact HP for assistance.

Troubleshooting using RAID Manager