3.

In the RCU Operation window Display box, select Port. The ports associated with the local
storage system are listed.

4.

Right-click the port that you want to configure and select the desired port type (Initiator, RCU
Target, or Target).

5.

When you have modified all the ports you want, review the Preview list.

To change the attribute that you set for a port, right-click the port in the full upper list and
select the new attribute.

To cancel a modification, right-click the port in the Preview list and select Delete.

6.

When you are satisfied, click Apply to save your modifications in the system.

Configuring storage systems, defining logical paths

You configure the primary and secondary system for Continuous Access Synchronous by adding
an RCU—a secondary storage system—to the primary storage system. This prepares both systems
for Continuous Access Synchronous commands and operations. During the procedure, logical
paths are also defined.

Prerequisite information

This procedure is performed on the primary system.

The primary and secondary system must be ready for Continuous Access Synchronous
operations. See

Storage system preparation (page 15)

for more information.

The data path must be set up. See

Data path requirements and configurations (page 33)

for

more information.

The port attributes on the primary and secondary system must be configured for Continuous
Access Synchronous. See

Defining port attributes (page 47)

.

The secondary system serial number, LDKC, controller ID, path group ID, and port numbers
are required. The secondary SSID may also be required.

48

Configuration operations