Troubleshooting Information

Table E-5: Are either of the Processor Board attention LED’s located on the front
bezel illuminated?

continued

Status Action

Processor board 2 attention LED is illuminated
and processor board 1 is installed.

•

Check the interconnect LEDs on the front
top edge of the power and media module to
see if the board is seated.

•

If processors were just added, be sure that
all processors on the board are the same
cache size and speed.

•

Processors on board 2 may not be of the
same cache size or speed as processors
on board 1.

•

Check connector for bent pins.

•

If video is available, look for additional
information contained within the POST
error messages

Both processor board 1 and processor board 2
LEDs are illuminated.

•

Check the interconnect LEDs on the front
top edge of the power and media module to
see if the boards are seated.

•

If processors were just added, be sure that
all processors on both boards are the same
cache size and speed.

HP ProLiant DL740 Server User Guide

E-11

HP CONFIDENTIAL

Writer: Anna Roberts File Name: o-appe Troubleshooting Information.doc

Codename: Expedition Part Number: 270854-002 Last Saved On: 6/17/03 2:41 PM