HP Surestore 64 Director Switch User Manual
Page 100

88 show
Output
The port information data is displayed as a table that includes the following properties.
Output Example
The output from the show.port.info command displays as follows.
Port WWN OpSpeed SpeedCap
---- ----------------------- ------- --------
0 10:00:80:00:11:22:33:44 1G 1G
1 10:00:80:01:11:22:33:44 1G 1G
2 10:00:80:02:11:22:33:44 1G 1G
3 10:00:80:03:11:22:33:44 1G 1G
4 10:00:80:04:11:22:33:44 1G 1G
5 10:00:80:05:11:22:33:44 1G 1G
6 10:00:80:06:11:22:33:44 1G 1G
7 10:00:80:07:11:22:33:44 1G 1G
8 10:00:80:08:11:22:33:44 1G 2G
9 10:00:80:09:11:22:33:44 1G 2G
10 10:00:80:10:11:22:33:44 1G 2G
11 10:00:80:11:11:22:33:44 1G 2G
12 10:00:80:12:11:22:33:44 1G 1G
13 10:00:80:13:11:22:33:44 1G 1G
14 10:00:80:14:11:22:33:44 1G 1G
15 10:00:80:15:11:22:33:44 1G 1G
Port
The port number.
WWN
The world-wide name of the port.
OpSpeed
The current operating speed (1G, where G represents gigabits).
SpeedCap
The current transceiver capability speed (1G or 2G, where G represents
gigabits).