Output
The event log data are displayed as a table that includes the following properties.
Output Example
The output from the show.eventLog command displays as follows.
Date/Time Code Severity FRU Event Data
---------------- ---- -------- ----- -----------------------------------
04/12/01 10:58A 375 Major CTP-0 00010203 04050607 08090A0B 0C0D0E0F
04/12/01 09:58A 385 Severe CTP-0 00010203 04050607 08090A0B 0C0D0E0F
04/11/01 07:18P 395 Severe CTP-0 00010203 04050607 08090A0B 0C0D0E0F
Date/Time
The date and time when the event occurred.
Code
The event reason code.
Severity
The severity of the event. The values are:
Major—Unit operational (major failure).
Minor—Unit operational (minor failure).
Severe—Unit not operational. The causes are either the switch contains no
operational SBAR cards or the system shutdowns due to CTP thermal
threshold violations.
Info—Unit operational (information only).
FRU
The FRU and FRU position, where applicable.
Event Data
The 32-byte hexidecimal description of the event in words.