Configuring cross-subsystem path, Configuring, Cross-subsystem path – HP XP External Storage Software User Manual

Page 81: Ge81

Advertising
background image

Configuring Cross-subsystem Path

You can configure the cross-subsystem path using the Configure Cross-subsystem Paths dialog box. This

section explains the procedure to add a cross-subsystem path to an existing path group. To create a new

path group and configure cross-subsystem paths, you need to operate the mapping operation. For the

procedure, see

Mapping an External Volume Automatically

” on page 69.

To add the cross-subsystem path to an existing path group:

1.

Start Remote Web Console, and open the Volume Operation window.

2.

Make sure that Remote Web Console is in Modify mode.

3.

Click the path group that you want to add a cross-subsystem path in the Volume Operation tree.

4.

Right-click the cross-subsystem path in Cross-subsystem Paths in the Volume Operation list.

A pop-up menu is displayed.

5.

Click Configure Cross-subsystem Paths in the pop-up menu.

The Configure Cross-subsystem Paths dialog box is displayed (see

Configure Cross-subsystem Paths Dialog Box

” on page 78).

6.

In the Available Paths, click the following three items, and then right-click the WWN in the

WWN (see

Figure 41

on page 82).

• External storage system: Click the external storage system.
• Port: Click the external port of the local storage system which is the starting point of the

cross-subsystem path.

• WWN: Click the WWN of the external storage system which is the ending point of the

cross-subsystem path.

Note:

When the external storage system or the WWN that you want to choose is not displayed

in the dialog box, you can update the information by clicking the Port Discovery button, selecting

the port which connects to the WWN, and then clicking OK.

A pop-up menu is displayed.

7.

Click Add in the pop-up menu.

The cross-subsystem path is added to the Selected Paths with the selected information. Configure

more than two cross-subsystem paths for one path group. Change the priority or delete

unnecessary cross-subsystem paths if necessary.

8.

Click OK to close the Configure Cross-subsystem Paths dialog box.

You are returned to the Volume Operation window. The settings are displayed in blue and italics.

9.

Verify the settings in the Preview dialog box (see “

Preview Dialog Box

” on page 57).

10.

Click Apply in the Volume Operation window.

The settings are applied to the local storage system and the Volume Operation window is

displayed normally. When an error occurs, an error message is displayed. Verify the details

in the Preview dialog box.

XP24000 External Storage Software User’s Guide

81

Advertising
This manual is related to the following products: