Nsc storage system) – HP XP External Storage Software User Manual

Page 120

Advertising
background image

Troubleshooting for External Storage

” on page 107. If you cannot restore the path, call HP technical

support.

Table 29 Path Status and Examples of Recovery Procedure (For USP V Storage System)

Path Status

Examples of Recovery Procedure

External device setting

changed

Settings of the LU paths may have been changed by LUN Manager.
Check the settings of the LU paths. If the settings of the LU paths have been

changed, change the settings back to the ones when the volume is mapped.

Or use External Storage to perform the Delete Volume operation and perform

the Add Volume operation again.
The access attribute of the volume may have been changed by Data Retention

Utility.
Check the access attribute of the volume. If the volume is protected by the

access attribute, release the protection.

Illegal request or
Response error

The volume may have been set as a pair volume for data copy.
Check if the volume is set as a pair volume of Business Copy, Continuous

Access, Continuous Access Journal or some other copy program. If the volume

is set as a pair volume, the volume may be protected because of the pair

status. When the volume is protected, change the pair status or delete the pair.
The access attribute of the volume may have been changed by Data Retention

Utility.
Check the access attribute of the volume. If the volume is protected by the

access attribute, release the protection.

Cannot detect port

There is a problem with connection to the external storage system. The

following are possible causes:

The fibre cable is not physically connected in the proper way.

The setting of the topology does not match between the external port

and the target port.

If the external storage system is connected through switches, the settings

for the switches may not be appropriate.

Check if the fibre cable is connected properly, and then set the Fibre Channel

port properly using LUN Manager.
The LUN security may have been enabled by LUN Manager.
Check if the LUN security is enabled or not. If the LUN security is enabled,

disable the LUN security.

TagmaStore USP Storage System, TagmaStore NSC Storage

System

When you connect a TagmaStore USP storage system or TagmaStore NSC storage system as the external

storage system, you need to set the port to the host group for the Windows hosts (host mode 0C:

Windows, host mode 2C: Windows Extension).
Also, the port attribute must be the target port or the RCU target port.

Path Status and Examples of Recovery Procedure (For TagmaStore USP Storage

System, TagmaStore NSC Storage System)

This section describes errors which requires recovery operation on the external storage system

side when the path status is not normal. When the path status is not normal, see the following

table to recover the path status. For the other errors which are not described in this section, see

Troubleshooting for External Storage

” on page 107. If you cannot restore the path, call HP technical

support.

120

Connecting External Storage Systems