Sense data errors, Not ready sense key codes – HP Integrity NonStop H-Series User Manual

Page 155

Advertising
background image

Troubleshooting

Library Media Manager Installation and User’s Guide529970-001

C -15

Sense Data Errors

Sense Data Errors

Sense Data messages LMM will display in EMS

NOT READY SENSE KEY CODES

If a command is sent when the library is not ready, it generates a Not Ready error

code. The following codes describe the conditions of the library that can generate

Not Ready codes.

NOT READY, CAUSE NOT REPORTABLE

LMM Message: 240: Sense Data - Not Ready, Cause Not Reportable

Explanation:

The library detected a not ready state after execution of the command was started.

NOT READY, IN PROCESS OF BECOMING READY

LMM Message: 241: Sense Data - Not Ready, In Process of Becoming Ready

Explanation:

The library is initializing and performing an audit. Initialization occurs in a

number of situations, including power-on, after the door has been opened then

closed, as part of the Send Diagnostic command, when requested from the operator

panel, and as part of a recovery during certain failures.

NOT READY, MANUAL INTERVENTION REQUIRED

LMM Message: 243: Sense Data - Not Ready, Manual Intervention Required

Explanation:

Manual intervention errors include: the front door is open, the CAP is open, the

library is in maintenance mode, or the library is in an inoperable state.

Description

Sense

Key

ASC

ASCQ

Not Ready, Cause Not Reportable

2h

04h

00h

Not Ready, In Process of Becoming Ready

2h

04h

01h

Not Ready, Manual Intervention Required

2h

04h

03h

Not Ready, Maintenance Mode

2h

04h

81h

Not Ready, Cartridge Access Port Open

2h

3Ah

02h

Not Ready,Cleaning Cartridge Installed

2h

30h

03h

Advertising