Troubleshooting

Library Media Manager Installation and User’s Guide529970-001

C -22

UNIT ATTENTION SENSE KEY

UNIT ATTENTION SENSE KEY

The library generates a Unit Attention sense key for all initiators if the library

needs to inform the host of an asynchronous event.

INSUFFICIENT RESERVATION RESOURCES

LMM Message: 6291: Sense Data - Unit Attention, Power-On Occurred

Explanation:

The library generates this type of Unit Attention when the library is powered-on,

IPLed from the operator panel, or reset over the SCSI bus. A Unit Attention is

generated for all initiators.

SCSI BUS RESET

LMM Message: 6292: Sense Data - Unit Attention, SCSI Bus Reset

Explanation:

The library generates this type of Unit Attention to all initiators after the SCSI

bus is clear of all I/O processes following a hard reset.

BUS DEVICE RESET MESSAGE OCCURRED

LMM Message: 6292: Sense Data - Unit Attention, Bus Device Reset Message Occurred

Explanation:

The library generates this message to all initiators after the library is clear of

all I/O processes following a hard reset.

NOT READY TO READY TRANSITION

LMM Message: 6280: Sense Data - Unit Attention, Not Ready-to-Ready Transition

Description

Sense

Key

ASC

ASCQ

Power-On Occurred

6h

29h

01h

Not Ready-to-Ready Transition

6h

28h

00h

CAP Element Accessed

6h

28h

01h

Mode Parameters Changed

6h

2Ah

01h

Reservations Preempted

6h

2Ah

03h

Reservations Release

6h

2Ah

04h

Registrations Preempted

6h

2Ah

05h

Microcode Has Been Changed

6h

3Fh

01h

SCSI Bus Reset

6h

29h

02h

Bus Device Reset Message Occurred

6h

29h

03h