Ethernet networks (advanced settings), Server vlan tagging support, Ethernet networks (advanced – HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual

Page 96: Settings)

Advertising
background image

Virtual Connect networks 96

Task

Action

Filter by Profile

Filter the list by a specific profile Select All Profiles or a single profile from the Filter by Profile profiles list.

The assigned networks are listed by each subport. If multiple networks are
assigned, mouse over the label to see a listing of all networks associated

with the subport.

Filter by Physical Server

Filter the list by server bay

Select All Bays or a single bay from the Filter by Physical Server bay list.
The list displays the actual server type installed in the bay, for example,

"Server Bay 1 HP ProLiant BL420c Gen8." If more than one enclosure is

imported into the domain, options are grouped according to the enclosure
name.

Filter the list by server port

Select All Ports or a single port from the Filter by Physical Server port list.

Accept selected ports and return
to the Port Monitoring screen

Click OK.

Clear newly selected ports
without saving and return to the

Port Monitoring screen

Click Cancel.

Reset the filter criteria to include
all items in each filter

Click Reset Filters.

Only display selected ports

Select the Only display selected ports check box.

Ethernet Networks (Advanced Settings)

Use this screen to perform the following tasks:

Set Server VLAN Tagging Support (on page

96

).

Set VLAN Capacity (on page

97

).

Use the Multiple Networks Link Speed Settings (on page

97

) to set a custom value for preferred link

connection speed or maximum link connection speed.

Enable or disable MAC Cache Failover (on page

98

).

Modify the refresh interval for MAC Cache Failover (on page

98

).

Enable or disable Network Loop Protection (on page

98

) for all VC-Enet modules in the domain.

Reset Network Loop Protection for all server ports in a loop-detected error state.

Enable or disable Pause Flood Protection (on page

100

) for all VC-Enet modules in the domain.

Reset Pause Flood Protection for all server ports in a pause flood protected error state.

Enable and configure Throughput Statistics ("

Configuring Throughput Statistics

" on page

100

) for all

ports of each VC-Enet module, including Flex-10 subports.

Configure domain wide LACP timer ("

LACP timer configuration

" on page

101

).

Server VLAN tagging support

VLAN tunneling support

Advertising