Hp server rx4610 sel data tables, Hp server rx4610 generator id codes – HP Integrity rx4610 Server User Manual
Page 175

Chapter 11
Troubleshooting
167
3. Replace the DC-DC Converters.
If the HP Server’s SCSI Drives Are Not Recognized
Check the following if the SCSI drives are not recognized during POST:
1. Check the seating of the Internal SCSI Cable between the I/O Board and
the Power Distribution Board (T-Docking).
2. Check that the SCSI drives are enabled in the BIOS Setup.
If the HP Server’s IDE Drives Are Not Recognized
Check the following if the IDE drives are not recognized during POST:
1. Check the seating of the IDE cables and power cables.
2. Check that the IDE drives are enabled in the BIOS Setup.
HP Server rx4610 SEL Data Tables
The tables in this appendix provide information on the SEL viewer data on the HP
Server rx4610 server platform.
HP Server rx4610 Generator ID Codes
Generator ID
Description
20 00
BMC
28 00
CBC
C0 00
HSC