HP Integrity rx4610 Server User Manual
Page 189

Chapter 11
Troubleshooting
181
Table 11-2. First Row Detection Order
Order
Row
Board
DIMM
1
C Upper
5-8
2
D Upper
13-16
3
E Upper
21-24
4
F Upper
29-32
5
8 Upper
1-4
6
9 Upper
9-12
7
A Upper
17-20
8
B Upper
25-28
9
4 Lower
5-8
10
5 Lower
13-16
11
6 Lower
21-24
12
7 Lower
29-32
13
0 Lower
1-4
14
1 Lower
9-12
15
2 Lower
17-20
16
3 Lower
25-28
Upon completion of the first row memory test, the memory testing continues with
the base memory test.
If the first row test fails, there are several possible failing cases. Two failing
scenarios are described in the following sections.
Case 1
The first row memory test encounters a MBE (Multi Bit Error) in the first
populated row of memory configured. Irrespective of the number of DIMMs
populated in the system, if the first row test encounters a MBE, the BIOS will
display an error message on the front panel LCD and halt the system.
User Notification
This memory test occurs during POST and prior to video sync. Therefore, any
error found during this test will result in the following message displayed on the
LCD panel.
“First row test”
“Failed, sys halt”