Requirements – HP Integrity rx4610 Server User Manual
Page 208

Appendix A
Specifications
200
Requirements
The following tables provide the specifications required for normal operation of
the HP Server.
Table A-1. Power Supply Specifications
Parameter
Characteristics
Input Power
208/110 VAC
Input Range –
Maximum
Dual rating:
800W minimum over 180-264 VAC
700W minimum over 90-132 VAC
Operating Current
100 VAC 5.3 A
120 VAC 4.6 A
200/208 VAC 3.2 A
220/230 VAC 2.8 A
In-rush Current
25 A
Output Voltages
+48 V
+12 V standby
Operating Power
256 W Continuous
Table A-2. Environmental Requirements
Parameter
Conditions
Temperature
Operating
5 °C to 35 °C (41 °F to 95 °F).
Non-operating
Humidity
Operating
20% to 80% relative humidity, non-condensing
Non-operating
5% to 95% relative humidity, non-condensing
Altitude
Operating
-30 to 3,000 m (~ 10,000 ft)
Non-operating
-30 to 12,000 m (~ 40,000 ft)
Thermal Output
Maximum Operating
1007 BTU/hr