HP StorageWorks Disk Array XP RAID Manager: User’s Guide
This option is effective without specification of the
–g group
option.
If the specified LDEV is listed in multiple device
groups, this applies to the first one encountered.
seq # LDEV #
can be specified in hexadecimal (by the
addition of 0x) or decimal.
–f
fence [CTGID] (CA only) Specifies a data-consistency level.
Valid values:
async CTGID (CA-Async and CA-Journal only)
data
status
never
CTGID
(CT group ID) is assigned automatically, but
the async option terminates with EX_ENOCTG when
beyond the maximum number of CT groups.
Maximum number:
XP256
16
(0-15)
XP512/XP48
64
(0-63)
XP1024/XP128
128
(0-127)
XP10000
256
(0-255)
XP12000
256
(0-255)
The CTGID option forces creation of paired volumes
for a given CTGID group.
-FCA
[ MU# ] or -FHORC [MU#]
Creates the cascading configuration with -g <group>
and -gs <group> option from the local node (takeover
node).
-g
<group> specifies the cascading PVOL
-gs
<group> specifies the cascading SVOL.
Ignores the -vl or -vr option because the SVOL will be