HP XP RAID Manager Software User Manual
Page 160

160
HP StorageWorks Disk Array XP RAID Manager: User’s Guide
BC Operation
The figure below shows the usage of the –FBC option. In the example, the
command tests the status of the intermediate S-VOL/P-VOL (MU#1)
through a specified pair group in a CA environment.
Syntax
pairevtwait –h
pairevtwait
{ –nomsg | –d pair_vol | –d[g] raw_device [ MU# ]
| –d[g]
seq# LDEV#
[ MU# ] | –FCA [ MU# ] | -FBC [ MU# ] | –g group | –h | –l
|–nowait |
–q | –s status . . .| –t timeout [ interval ] | –z[x] }
Arguments
–nomsg
Used to suppress messages when this command is
executed from a user program.
This option must be specified at the beginning of the
command arguments.
–d pair_vol
Specifies a paired volume name written in the
configuration definition file. The command executes
only for the specified paired volume.
–d
[g] raw_device [ MU# ]
(HP-UX, Linux, Solaris, Windows NT/2000/2003, AIX,
and MPE/iX only)
Searches the RM configuration file
(local instance) for a volume that matches the specified
PVOL
S/P
VOL
SVOL
SVOL
Ora(CA)
Oradb1(BC)
Oradb2(BC)
0
1
0
Seq#30052
Seq#30053
CA environment
pairevtwait -g ora -s psus -t 10 -FBC 1