HP XP RAID Manager Software User Manual
Page 207

207
defined in the local instance configuration definition
file).
If this option is specified, the –f[f] and –f[g] options are
invalid.
–f[e]
Displays the serial number and LDEV number of the
external LUNs mapped to the LDEV.
If the external LUN mapped to the LDEV on a
specified port does not exist, then this option will do
nothing. If this option is specified, the -f[f][g][d]
options are not allowed.
Example
# raidscan -p cl1-a-0 -fe -CLI
PORT# /ALPA/C TID# LU# Seq# Num LDEV# P/S Status Fence E-Seq# E-LDEV#
CL1-A-0 ef 0 0 48 62468 2 256 SMPL - - 30053 17
CL1-A-0 ef 0 0 49 62468 2 272 SMPL - - 30053 23
CL1-A-0 ef 0 0 50 62468 1 288 SMPL - - 30053 28
28
E-Seq#. Displays the production (serial) number of the
external LUN.
E-LDEV#. Displays the LDEV# of the external LUN.
–find
(HP-UX, Linux, Solaris, Windows NT/2000/2003, and
MPE/iX only)
Used to display the Port, targetID, LUN
(in RAID Manager notation) that was mapped to a
LDEV using a special (raw device) file provided via
STDIN.
If the target and LUN are unknown, this option can be
used to discover the Port, targetID, LUN associated
with a host device file so that the information can be
included in a horcm.conf file.