HP XP RAID Manager Software User Manual
Page 91

Using RAID Manager
91
d
If no $HORCMPERM file exists, then the following commands can be
manually executed to permit the use of all volumes the host is currently
allowed to see (LUN security products may or may not be in place).
HP-UX
ioscan –fun | grep rdsk | /HORCM/usr/bin/raidscan –find inst
Linux
ls /dev/sd* | /HORCM/usr/bin/raidscan –find inst
Solaris
ls /dev/rdsk/* | /HORCM/usr/bin/raidscan –find inst
AIX
lsdev –C –c disk | grep hdisk | /HORCM/usr/bin/raidscan –find
inst
If the lsdev command does not show the TID and LUN (for example,
2F-00-00-2,0) in the column output for the devices as shown below, then
the –d[g] raw device option (on all commands) and raidscan –find will be
unable to find target devices.
# lsdev
–
C
–
c disk
hdisk1 Defined 04-02-01 Other FC SCSI Disk Drive
This happens when a Fibre Channel adapter is used with a different device
driver (for example, an Emulex adapter with an AIX driver).
MPE/iX
callci dstat | /HORCM/usr/bin/raidscan -find inst
Windows NT/2000/2003
echo hd0-999 | x:\HORCM\etc\raidscan.exe -find inst
The MAX volume to be scanned is 1000 by default.