HP XP RAID Manager Software User Manual
Page 200

200
HP StorageWorks Disk Array XP RAID Manager: User’s Guide
PFUS
Since the PFUS state is referring to a Suspend state
with the Side File Full, the PFUS state is displayed as
PSUS by all commands except pairvolchk and the –fc
option of the pairdisplay command.
SVOL_PSUS
Displayed as SSUS by the pairdisplay command.
Error Codes
The table lists specific error codes for the pairvolchk command.
Examples
CA Async:
# pairvolchk -g oradb
pairvolchk:Volstat is P-VOL.[status=PAIR fence=ASYNC CTGID=2 MINAP=2
CA Sync:
# pairvolchk -g oradb
pairvolchk : Volstat is P-VOL.[status = PAIR fence = DATA MINAP = 2
LDEV =BLOCKED]
“MINAP” shows the minimum active paths to a specified group on the
P-VOL. If the array firmware does not support tracking the number of
active paths, then "MINAP" will not be displayed (as below).
“LDEV = BLOCKED indicates failure to link to an E-LUN by CA
BC:
# pairvolchk -g oradb
pairvolchk : Volstat is P-VOL.[status = PAIR ]
BC with CT Group:
# pairvolchk -g oradb
pairvolchk : Volstat is P-VOL.[status = PAIR CTGID = 1 ]
Category
Error Code
Error Message
Value
Volume status
unrecoverable
EX_ENQVOL
Unmatched volume status within the group
236
EX_EVOLCE
Pair volume combination error
235