You can verify that the HORCM daemon is running as a detached process
by using the SHOW PROCESS command.

$ show process horcm0

25-MAR-2003 23:27:27.72 User: SYSTEM Process ID: 00004160

Node: VMS4 Process name: "HORCM0"

Terminal:

User Identifier: [SYSTEM]

Base priority: 4

Default file spec: Not available

Number of Kthreads: 1

Soft CPU Affinity: off

$

$ horcmshutdown 0 1

inst 0:

HORCM Shutdown inst 0 !!!

inst 1:

HORCM Shutdown inst 1 !!!

$

Command device

With OpenVMS, RAID Manager uses the SCSI Class driver to access the
RAID Manager command device on the XP array, and defines “DG* or
DK*” as the logical name for the device.

You will need to define the physical device as either DG*, DK* or GK*
by using the DEFINE/SYSTEM command for RM versions 01.12.03
and earlier.

$

$ run /DETACHED SYS$SYSTEM:LOGINOUT.EXE /PROCESS_NAME=horcm1 -

_$ /INPUT=VMS4$DKB100:[SYS0.SYSMGR.][horcm]loginhorcm1.com -

_$ /OUTPUT=VMS4$DKB100:[SYS0.SYSMGR.][horcm]run1.out -

_$ /ERROR=VMS4$DKB100:[SYS0.SYSMGR.][horcm]run1.err

%RUN-S-PROC_ID, identification of created process is 00004166