Capacity list for each emulation type, Calculating lu capacity (open-3 example), Ldev capacity information for each emulation type – HP StorageWorks XP Remote Web Console Software User Manual

Page 181

Advertising
background image

Figure 71 Calculating LU capacity (OPEN-3 example)

.

Capacity list for each emulation type

This section explains the LDEV capacity and volume capacity for each emulation type in the units of
blocks and cylinders.

Table 33

lists the minimum data area capacity, base data area capacity, and control information

area capacity for each emulation type. For the OPEN-L emulation type, CVs cannot be created.
Therefore, the base data area capacity and minimum data area capacity for OPEN-L emulation type
are the same. For the OPEN-V emulation type, the base data area capacity is not listed because there
is no concept of the base data area capacity.

In this section, the numbers of cylinders are calculated from the following formulas.

For 3380 mainframe volumes: 1 cylinder = 1,440 blocks

For 3390 mainframe volumes: 1 cylinder = 1,740 blocks

Table 33 LDEV capacity information for each emulation type

Control information
area capacity

Base data area capacity

Minimum data area capa-
city

Emulation type

cylinders

blocks

cylinders

blocks

cylinders

blocks

7

10,080

3,339

4,808,160

50

72,000

3380-3

7

10,080

3,339

4,808,160

50

72,000

3380-3A

7

10,080

3,339

4,808,160

50

72,000

3380-3B

XP External Storage Software User Guide