Edit external wwns wizard, Edit external wwns window – HP XP P9500 Storage User Manual

Page 116

Advertising
background image

Edit External WWNs wizard

Edit External WWNs window

QDepth

The number of Read/Write commands which can be issued (queued) to the external volume at a
time. The value that can be set ranges from 2 to 128. 8 is input by default.
The value set to the selected external path is displayed. When two or more paths with different
values are selected, blank is displayed by default.

I/O Timeout

Value specified as the time over of the I/O to the external volume. The value that can be set ranges
5 to 240 (in second). 15 is input by default.
The value set to the selected external path is displayed. When two or more paths with different
values are selected, blank is displayed by default.

Path Blockade Watch

The time from when the connection of all the paths to the external volume have been down to when
the external volume is blocked. The commands from the host are accepted until the time set for this
parameter has passed. After the time set for this parameter has passed, the path status becomes
Blockade. The value that can be set ranges from 5 to 180 (seconds). 10 is input by default.
The value set to the selected external path is displayed. When two or more paths with different
values are selected, blank is displayed by default.

116

External Storage GUI reference