EMC CLARiiON CX series

When you connect an EMC CLARiiON CX series as an external storage system, set the system
parameters of the EMC CLARiiON CX series according to the following table. For system parameters
not in the following table, see the EMC CLARiiON CX series documentation and set the parameters
appropriately for the connecting configuration.

Table 27 System parameters (EMC CLARiiON CX series)

Parameter setting

Parameter

CLARiiON Open

Initiator Type

2

Failover Mode

Notes on connecting EMC CLARiiON CX series

Volumes created with Individual Disk Units (JBOD disks) of EMC CLARiiON CX series are not
supported.

EMC Symmetrix series

System parameters for connecting EMC Symmetrix series

When you connect an EMC Symmetrix series as an external storage system, set the system
parameters of the EMC Symmetrix series according to the following table. For the system parameters
that are not in the following table, see the documentation of the EMC Symmetrix series and set the
parameters appropriately for the connecting configuration.

Table 28 System parameters for connecting EMC Symmetrix series

Parameter setting

Parameter

Enable

SC3 flag

Disable

SPC2 flag

IBM DS3000/DS4000/DS5000 series

When connecting an IBM DS3000/DS4000/DS5000 series as an external storage system, set
the system parameters of the IBM DS3000/DS4000/DS5000 series according to the following
table. For the system parameters that are not in the following table, see the documentation of the
IBM DS3000/DS4000/DS5000 series and set the parameters appropriately for the connecting
configuration.

Table 29 System parameter (IBM DS3000/DS4000/DS5000 series)

Parameter setting

Parameter

When alternate paths are connected to different clusters on the
DS3000/DS4000/DS5000 series side: Linux

host type

System parameters for connecting IBM SVC series

When connecting an IBM SVC series as an external storage system, set the system parameters of
the IBM SVC series according to the following table. For the system parameters that are not in the
following table, see the documentation of the IBM SVC series and set the parameters appropriately
for the connecting configuration.

Table 30 System parameters (IBM SVC series)

Parameter setting

Parameter

Generic

host type

EMC CLARiiON CX series