Figure 3 Example of the Auto LUN operation

Continuous Access Synchronous operations

Figure 4 (page 15)

shows the use of an external volume for the Continuous Access Synchronous

operation. The mapped external volume is set as the S-VOL of the Continuous Access Synchronous
pair, and the volume in the local storage system that is connected as the multipoint control unit
(MCU) is set as the P-VOL of the Continuous Access Synchronous pair. For details on Continuous
Access Synchronous, see the HP P9000 Continuous Access Synchronous User Guide.

The procedure for the operation is as follows:
1.

Use External Storage to map a volume in the external storage system as an internal volume
of the local storage system, which is used as remote control unit (RCU) for the Continuous
Access Synchronous operation.

You can select the emulation type of the mapped volume as you required. If you select the
emulation type for the open system (such as OPEN-V), go to step 2. If you select the emulation
type for the mainframe system (such as 3390-3), go to step 3.

2.

If you set the emulation type for the open system when you map the volume, the status of the
mapped volume automatically becomes Normal. However, the volume formatting processing
is not executed automatically. If you need to format the mapped volume, format the volume
using the Virtual LUN function.

For the volume formatting operation procedure, see the HP P9000 Provisioning for Open
Systems User Guide
.

Go to step 4.

3.

If you set the emulation type for the mainframe system when you map the volume, the status
of the mapped volume becomes Blockade. Format the volume using the Virtual LVI function.
Or if you have mapped the volume for which the data area has already been zero-formatted
on the external storage system side, perform the Write to Control Blocks operation using the
Virtual LVI function to restore the volume.

For the volume formatting operation procedure and the Write to Control Blocks operation
procedure, see the HP P9000 Provisioning for Mainframe Systems User Guide.

Go to step 4.

4.

Set the P-VOL and S-VOL of the Continuous Access Synchronous pair.