HP StorageWorks XP Remote Web Console Software User Manual

Page 61

Advertising
background image

1.

If you need to terminate the I/O operation on the volumes of TrueCopy Synchronous for
Mainframe pairs to maintain the consistency of data, terminate the I/O operation.

2.

Use the ICKDSF command to create a Version 2 pair. See the following example:

FLASHCPY ESTABLISH UNIT(X'dev#') TARGETVOL(X'ssid',X'cca',lss) ONLINTGT(YES)

If the Version 2 S-VOL and TrueCopy Asynchronous for Mainframe R-VOL are shared:

1.

If you need to terminate the I/O operation on the volumes of TrueCopy Asynchronous
for Mainframe pairs to maintain the consistency of data, terminate the I/O operation.

2.

Suspend the TrueCopy Asynchronous for Mainframe pair. See the following example:

CSUSPEND DEVN(X dev#') PRIM(X ssid' cmd_param X cca X lss) SEC(X ssid' serial# X cca X lss)

3.

Use the ICKDSF command to create a Version 2 pair. See the following example:

FLASHCPY ESTABLISH UNIT(X'dev#') TARGETVOL(X'ssid',X'cca',lss) ONLINTGT(YES)

4.

Resynchronize the TrueCopy Asynchronous for Mainframe pair.

If the Version 2 T-VOL and TrueCopy Synchronous for Mainframe M-VOL are shared:
1.

To maintain the consistency of data, terminate the I/O operation to the volumes of
TrueCopy Synchronous for Mainframe pairs. The TrueCopy for Mainframe pair status is
Duplex.

2.

Use the ICKDSF command to establish a Version 2 relationship. See the following
example:

COPY FULL INDYNAM(xxxxxx) OUTDYNAM(yyyyyy) FASTREP(REQ) FCCOPY TCTOPPRCPRIMARY

Using Version 2 with Universal Replicator for Mainframe

“Whether Version 2 Can be Used as a Universal Replicator for Mainframe Volume” (page 61)

describes the combination of volumes allowed when you use Version 2 with Universal Replicator
for Mainframe.

Table 34 Whether Version 2 Can be Used as a Universal Replicator for Mainframe Volume

Universal Replicator for Mainframe

Version 2

S-VOL

P-VOL

No

Yes

S-VOL

No

No

T-VOL

When you use a Version 2 S-VOL as a Universal Replicator for Mainframe P-VOL

When you use a Version 2 S-VOL as a Universal Replicator for Mainframe P-VOL, you can
use it regardless of the status of the Universal Replicator for Mainframe pair.