External Paths tab

Displays the paths connecting mapped external volumes in the external system to HP XP7 Storage.

Description

Item

Local system port number.

Port ID

External system port identification number.

External WWN

Identifying information for the external system.

Vendor / Model / Serial Number

Status of external paths.

Status

Normal: There are no problems, the system is usable.

Disconnect: The path has been intentionally disconnected.

Checking: The system is checking the external path status.

Unknown: The status of the external path is not known.

Warning: There are external paths whose status is not normal. You can check
their status in the View External LUN Properties window.

Blockade: The external path is blocked.

Number of Read/Write commands that can be queued to the external volume.
8 is set by default.

QDepth

Number of seconds that should pass before I/O to the external volume times
out. 15 seconds is the default.

I/O Timeout (sec.)

Time that will elapse from the time that a path goes down to the time when the
external volume is blocked. 10 seconds is the default.

Path Blockade Watch(sec.)

When clicked, launches the Disconnect External Paths window.

Disconnect External Paths

When clicked, launches the Reconnect External Paths window.

Reconnect External Paths

External Storages window

101