Emc vnx series, System option mode for connecting emc vnx series, System parameters for connecting emc vnx series – HP XP Racks User Manual

Page 89: Emc symmetrix series

Advertising
background image

System parameters for connecting EMC CLARiiON CX series

When you connect an EMC CLARiiON CX series as an external storage system, set the system
parameters according to the following table.

Setting

Parameter

CLARiiON Open

Initiator Type

2

Failover Mode

Disabled

ArrayCommPath

For system parameters not shown in the table, see the EMC CLARiiON CX series documentation.

NOTE:

Volumes created with Individual Disk Units (JBOD disks) of EMC CLARiiON CX series

are not supported. Make sure to define the LU number for each port in the EMC CLARiiON CX
side.

EMC VNX series

System option mode for connecting EMC VNX series

When you connect an EMC VNX series as an external storage system, you must set SOM 725 of
the local storage system to ON. If SOM 725 is not set to ON, the external storage system might
be blocked when performing maintenance tasks such as rebooting the controller of the external
storage system before the firmware update.
For worldwide technical support information, see the HP support website:

http://www.hp.com/

support

.

System parameters for connecting EMC VNX series

When you connect an EMC VNX series as an external storage system, set the system parameters
of the EMC VNX series according to the following table:

Setting

Parameter

CLARiiON Open

Initiator Type

2

Failover Mode

Disable

ArrayCommPath

For system parameters not shown in the table, see the EMC VNX series documentation.

NOTE:

Volumes created with Individual Disk Units (JBOD disks) of EMC VNX series are not

supported. Make sure to define the LU number for each port in the EMC VNX side.

EMC Symmetrix series

The port must be configured as a target attached to a Windows host.
Set system parameters according to the following table. For connection parameters not shown,
refer to EMC Symmetrix series documentation

Parameter Setting

Parameter

Enable

SC3 flag

Disable

SPC2 flag

On the local HP XP7 Storage system, system option mode 745 needs to be ON.

EMC VNX series

89

Advertising
This manual is related to the following products: