For 3Par V800 and V400 series

Parameter Setting

Parameter

generic-legacy

host mode

The volumes in which "Dynamic optimization" or "Adaptive optimization" is applied must not be
used as the external volume of HP XP7 Storage; otherwise the performance of the external volume
may possibly be degraded and the operation cannot be guaranteed.

Storage system with a product name displayed as "(Generic)"

The generic External Storage profile (available with 70-04-x) provides support for connecting Fibre
channel attached, external storage systems without testing them individually. It will automatically
support storage systems that conform to a subset of the standard SCSI Primary Commands. (If you
need further information, please contact the HP Technical Support). An HP representative can
perform a step-wise process to install and connect external storage. These steps (defined below)
follow a standard process to ensure that no obvious problems exist in the virtualization. Updating
a HP XP7 Storage to the minimum firmware level 70-05-0x automatically installs the generic Ext
Stor profile and makes it available.

Support conditions when product name displays as “(Generic)”

When an external storage system is connected to a HP XP7 Storage and is supported with the
generic Ext Stor profile, the following support conditions exist.

Vendor name that corresponds to the external storage system is displayed.

Product name is displayed as “Generic”.

NOTE:

If multiple generic storage systems of the same vendor are connected, they are

displayed as a single storage system. As a result, if Disconnect External Storage Systems or
Reconnect External Storage Systems is run for generic storage systems, all the generic storage
system volumes are disconnected or reconnected. For disconnecting or reconnecting a particular
generic storage system volume, the best practice is to run the command in the external volume
unit rather than the external storage system unit.

Serial number is not displayed.

Characteristic1(device information). LUN assigned to the path with the highest priority is
displayed.

Path Mode and Load Balance Mode. Load Balance Mode is set to Disable by default. Three
Path Mode settings are available:
1.

Normal Round-robin (For Multi Path)

2.

Extended Round-robin (For Multi Path)

3.

Disable (For Single Path and ALUA)

By default, Load Balance Mode is set to Disable for the generic Ext Stor profile. As a result,
Ext Stor uses Single Mode (Active/Passive). If the attached external storage supports Multi
pathing (Active/Active), the Load Balance Mode setting must be changed to Extended
Round-robin or Normal Round-robin.

The Load Balance Mode can be changed in the Add External Volumes window of Remote Web
Console.