Determining capacity for mainframe volume other than 3390-A and 3390-V

For mainframe volumes other than 3390-A and 3390-V, an expanded control information area of
7 cylinders (12,180 blocks) is required for every 1,113 cylinders (1,936,620 blocks). The area
total includes the minimum or base data area and the control information area. Because the entire
LDEV capacity should be divided by 77,952 blocks, an adjustment area is also required.

Formula for calculating necessary LDEV capacities (in blocks)

ceil: rounding up the first decimal place to the nearest integer

Minimum LDEV capacity = ceil({ceil((Minimum data area capacity \
+ Control information area capacity) / 1,936,620) × 12,180 \
+ (Minimum data area capacity \
+ Control information area capacity)} / 77,952) × 77,952

LDEV capacity = ceil({ceil((Base data area capacity \
+ Control information area capacity) / 1,936,620) × 12,180 \
+ (Base data area capacity \
+ Control information area capacity)} / 77,952) × 77,952

Minimum LDEV capacity and Base LDEV capacity for mainframe systems

Base LDEV capacity (blocks)

Minimum LDEV capacity (blocks)

Emulation type

2,026,752

155,904

3390-1

3,975,552

155,904

3390-2