HUS/AMS/WMS

The table below shows the system parameters that must be specified for ports on HUS, AMS, and
WMS storage systems when used with External Storage. You can specify or omit any other
parameters.
Also, ensure the following two settings using Storage Navigator Modular or Storage Navigator
Modular2
:

Set the data transfer speed of the external port to a fixed value other than Auto.

Set the data transfer speed of the target port of the HUS/AMS/WMS storage system to a
fixed value consistent with the data transfer speed of the external port.

Parameter Settings

Parameters

Window Names

Start Attribute

Boot Options

Specify when HUS/AMS/WMS is in a one-controller
configuration.

Single Mode

Specify when HUS/AMS/WMS is a two-controller
configuration.

Dual Active Mode

Optional

Delay Planned Shutdown

Optional

Drive blocking mode

HITACHI (default-do not change)

Vendor ID

DF600F (default-do not change)

Product ID

Optional

ROM Microprogram Version

Optional

RAM Microprogram Version

Optional

Option

System Parameter

Reset of occurred.

Operation if the processor failure
occurs

Optional

WEB Title

For AMS 1000, AMS 500, AMS 200 and WMS 100:
ON

Write and verify mode

For HUS 150, HUS 130, HUS 110, AMS 2500, AMS
2300, AMS 2100, and AMS 2010: OFF

Optional

Port Option

Port Options

Set AMS common setting to Standard Mode.

Host Connection Mode 1

Host Connection
Mode

Do not specify any parameters for AMS additional
settings.

Host Connection Mode 2

For AMS 1000, AMS 500, AMS 200 and WMS 100,
do not specify HISUP OFF mode.