background image

Message name / description

ASCQ

ASC

Sense
key

ROTARY INVALID START CONDITION
Rotary hardware condition is unknown. Run the Robotics to Home Position
test from the OCP.

E0

82

5

ROTARY INVALID COMMAND
Rotary axis was commanded to a position out of its legal range. This is
an internal code failure.

•

Verify that the host software application is supported, has up-to-date
patches, and is correctly configured.

•

Verify that the library and its components have the current firmware.

F0

82

5

EXTENSION INVALID START CONDITION
Extension hardware condition is unknown. Run the Robotics to Home
Position test from the OCP.

E0

83

5

EXTENSION INVALID COMMAND
Extension hardware was commanded to a position out of the systems
mechanical limits.

•

Verify that the host software application is supported, has up-to-date
patches, and is correctly configured.

•

Verify that the library and its components have the current firmware.

F0

83

5

VERTICAL INVALID START CONDITION
Vertical hardware condition is unknown. Run the Robotics to Home
Position test from the OCP.

E0

84

5

VERTICAL INVALID COMMAND
Vertical hardware commanded to position out of system mechanical
limits.

•

Run the Robotics to Home Position test from the OCP.

•

If the problem persists, calibrate the library.

•

Verify that the host software application is supported, has up-to-date
patches, and is correctly configured.

•

Verify that the library and its components have the current firmware.

F0

84

5

HORIZONTAL INVALID START CONDITION
Horizontal hardware condition is unknown. Run the Robotics to Home
Position test from the OCP.

E0

85

5

HORIZONTAL INVALID COMMAND
Horizontal hardware commanded to position out of system mechanical
limits.

•

Run the Robotics to Home Position test from the OCP.

•

If the problem persists, calibrate the library.

•

Verify that the host software application is supported, has up-to-date
patches, and is correctly configured.

•

Verify that the library and its components have the current firmware.

F0