Troubleshooting
Problem: No Rate
Solution: 1. Make sure “Echo flow rate” is checked in the CAN simulator
2. Check that the modules are communicating with the display
a. Press the system diagnostics button
b. Choose the “CAN A” tab
i. You should have “232 DC Liquid” and “233 Aux Device” for a
liquid configuration
ii. You should have “232 DC Spreader” and 233 Aux Device” for a
granular configuration
iii. You should have “239 Speed Module”, “240 Flow Sensor” and
“244 Moisture Module” for a harvest configuration
c. Reboot display, simulator and/or computer
Problem: No DGPS
Solution: 1. Check which serial (communication) port you are connected to:
a.
Go to the start menu of Windows and choose control panel
b.
Choose system, then hardware
c.
Select device manager
d.
Expand ports (COM & LPT)
e.
This will tell you which port to use:
f. Set the port under Settings> Serial Port” in the GPS simulator program