Flex-a-Lite 35 Electric Fans: Puller mode, does not include controls User Manual

Model 30 or 35 electric fans, Diagram a

Advertising
background image

Model 35: Puller mode, does not include controls.

Optional Connection

*Illuminated Manual Switch(not included) Allows
manual operation of fan

(Note: based on Flex-a-lite’s

manual switch part #31148)
1. Connect the “M” terminal to terminal 1 on the switch.

2. Attach terminal 2 to a 12 volt positive (+) source.

3. Attach terminal 3 to ground to illuminate switch.

Note (optional): To stop the fan from activating thermo-
statically, omit the lead to the positive(+) terminal of the
control box. B, G, & M must remain connected.

Mandatory Connections

+ 12 volt low amp
source

Optional Connection

M Manual switch

G Ground
B 12 volt high amp

source

C Air conditioning relay

B

C

M

G

+

In Line Fuse

12 Volt Low Amp Source

1

2

3

Ground

3-way
Connector

12 Volt Source

Ground(Illuminate switch)

Control Box

A/C Positive Lead

12 Volt Positive

н

н

Model 30: Puller mode, includes thermostatic control.

Mandatory Connections for Model 30

1. Disconnect battery- negative terminal before proceeding with installation.

2. Connect the positive “+” terminal to a low amp 12 volt positive (+) power source (e.g. fuse box), using the wire provided in the

kit.

Note(optional): Attach positive (+) terminal to an ignition source to stop the fan unit from operating after the engine is
turned off.

3. Connect the “B” terminal to a high amp 12 volt positive (+) power source, ie. positive (+) side of battery or alternator, using the

wire and inline fuse included in kit.

4. Connect the “G” terminal to ground (negative (-) battery post perferred) using the wire provided in the kit.

5. With the wire and 3-way connector provided, splice into the A/C clutch positive(+) wire. Connect the other end of the wire to

the "C" terminal of the control box. Air Conditioning Relay Activates fan when A/C is turned on. If no A/C leave blank

6. Install provided knob onto the thermostat shaft.

7. Adjust thermostat to desired temperature within 180

0

-240

0

.

CCW is lower temp. CW is higher

*WARNING:

If not using Flex-a-lite's illuminated

switch (PN #31148) you must disconnect the switch
ground.

Model 30 or 35 Electric Fans

Diagram A

Speed Nut

Rectangular
Rubber Washer

Plastic
Washer

Nylon Bolt

The Flex-a-lite Limited Warranty
Flex-a-lite Consolidated, 7213-45th St. Ct. E. Fife, WA 98424, Telephone No. 253-922-2700, warrants to the original purchasing user, that all Flex-a-lite products to be free of defects
in material and workmanship for a period of 365 days (1 year) from date of purchase. Flex-a-lite products failing within 365 days (1 year) from date of purchase may be returned to
the factory through the point of purchase, transportation charges prepaid. If, on inspection, cause of failure is determined to be defective material or workmanship and not by misuse,
accidental or improper installation, Flex-a-lite will replace the fan free of charge, transportation prepaid. Flex-a-lite will not be liable for incidental, progressive or consequential
damages.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives
you specific legal rights and you may have other rights, which vary from state to state.
The Flex-a-lite warranty is in compliance with the Magnuson-Moss Warranty Act of 1975.

rev. 01-22-07 99976

1. Remove the vehicle's existing fan and shroud.

2. Position the electric fan against the back of the radiator (between the radiator & engine), and mark the holes for mounting.

3. Rotate the blades to make sure they are free of obstructions.

4. With a small phillips screwdriver, pass through the marked holes, carefully spreading the fins to allow easy passage for the nylon bolts.

Pass the bolts through the shroud holes then twist the bolts through the radiator.

5. Install rubber disc spacers, washers, and speed nut. Cut the excess off the bolt (Leave enough excess for adjustments).

6. If using a model 30, insert probe in radiator core near upper hose. Install rubber cap over end of probe.

Mounting Instructions--Model 30 or 35 may be installed either horizontally or vertically to
the radiator.

Advertising