2.4.1 Calibration

Schedule


Normally aspirated (daily driver)

- Calibrate before installation of new sensor
- Calibrate new sensor again after 3 month of use
- Thereafter calibrate once a year or every 20,000 miles, whichever comes
first

Turbo Application, daily driver (tuned rich)

- Calibrate before installation of new sensor
- Calibrate new sensor again after 3 month of use
- Thereafter calibrate twice a year or every 10,000 miles, whichever comes
first

Race Application

- Calibrate before first installation of new sensor
- Calibrate once per race weekend

2.5

Changing the MTX-L’s gauge face and/or bezel

1. Lay the MTX-L face down and remove the three #2 phillips screws

from the outside rim of the back plate.

2. Carefully lift out the bezel from the gauge cup.
3. Configure the gauge as desired by changing the gauge face and or

bezel.


*Be sure to remove protective film from the gauge face. This can be
done easily with a piece of scotch tape.

4. Make sure every piece is positioned correctly using the locating tab

and reassemble the gauge.

5. Reinstall

the

3 #2 phillips screws.

3