- 4 -

1.1 Differential

Inputs


The SSI-4’s external connections are differential. This means that each input channel has 2 input
terminals. A + terminal and a – terminal. This is to eliminate ground offsets in the signal. Many
times the ground point of a sensor is at a different ground than the SSI-4. Because an electronic
device can only measure a voltage referenced to it’s own ground, differences in grounding can
introduce measurement errors. The SSI-4 measures the sensor signal’s ground with the – input
and them measures the difference between the + and the – input. This way it “recreates” the
sensor signal’s own ground reference as if this input were referenced directly to that sensor’s
ground. The common mode rejection range is the maximum voltage this ground reference input
can differ from the SSI-4 ground.

The (–) input is NOT a ground itself. It is a ground reference input.

2. Specifications

Power

Power requirements

8-36 Volt / 50mA

1

Power reversal protection

Yes

External Sensor power

5V (+- 2.5%), 300mA max.

Serial Communication

Serial Port Speed

19.2 kbit/sec

Packet/Logging Speed

81.92 msec/sample packet

Sample Resolution

10 bits (0..5V at 0.1% resolution)

Input Specifications

Number of Channels

4

Input measurement range

0..5V

CHx+ max input voltages

- 22.5 Volt to +300 Volt

CHx- max input voltages

- 22.5 Volt to +27.5 Volt

Common Mode Rejection
Range

-22.5 Volt to +22.5 Volt

Input threshhold for pulsed
Signals

2.5V

Max Frequency

15 kHz

2

Input Impedance

1 MOhm

Temperature

Max Operating Temperature

-20 to +80 deg Celsius

Mechanical

Size (W x L x H)

133 x 65 x 26 mm

Weight 114

grams


Note 1:
Supply current specified does not include external sensor current supplied by 5V output.

Note 2:
Sum of all frequency/Duty Cycle signals connected should not exceed 15 kHz.