Yetter 2940 Short Floating Air Adjust Residue Manager User Manual

Page 84

Advertising
background image

84

COMPRESSOR TROUBLE SHOOTING

TOUBLESHOOTING CHART

PROBLEM

PROBLEM CAUSE(S)

CORRECTIVE ACTION

Tank pressure drops

1. Check valve leaking

when compressor

2. Loose connections

shuts off

Compressor runs

1. Excessive air usage

1. Decrease air usage

continuously and air

2. Loose connections

2. Check all connections with soap and

flow lower than
normal

3. Worn piston ring or inlet valve

water solution and tighten
3. Replace compressor

4. Clogged air filter element
5. Bad pressure switch
6. Defective safety valve


4. Replace air filter element
5. Replace pressure switch
6. Replace safety valve

Excessive moisture in 1. Excessive water in air tank

1. Drain tank, Drain tank more frequently

discharge

2. High Humidity

2. Move compressor to area with less

humidity, or use air line filter

CAUTION: NEVER DISASSEMBLE COMPRESSOR WHILE COMPRESSOR IS PRESSURIZED.

TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

Compressor will not
run

1. No power, or power switch is OFF

1. Make sure compressor switch is ON

position

2. Disconnect compressor from power

2. Blown fuse

source, replace fuse (Refer to

3. Motor overheats

Specifications section for correct fuse

4. Pressure switch bad.

amperage

3. Let compressor cool off for about 30

minutes to allow thermal overload switch
reset

4. Replace pressure switch

Thermal Overload

1. Lack of proper ventilation or

1. Move compressor to well ventilated

Protector cuts out

ambient temperature is too high

area, or area with lower ambient
temperature

repeatedly

2. Compressor valves failed

2. Repair or replace compressor

Excessive Knocking

1. Loose mounting bolts

1. Tighten bolts

or rattling

2. Worn bearing on eccentric or motor
shaft

2. Replace compressor

3. Cylinder or piston ring is worn

3. Rebuild compressor

1. Replace check valve or compressor
2. Check all connections with soap and

water solution and tighten

Advertising