Vaisala HMP230 User Manual

Page 27

Advertising
background image

HMP230 SERIES

M210225en-B

User's Guide

21

•

slip the brass disk that has the bigger hole in it over the braid so that
it rests against the cable insulation

•

slip the other brass disk over the wires to the middle of the braid

(If the cable diameter is less

than 7mm, use a shrinking

tube or an adhesive tape)

cable

braid

flexible wires 0.5 mm²

(AWG 20), stranded wires

recommended

D = Ø 7...10 mm

3

brass
disks

25

rubber
ring

nut

brass disks

140

165

shielding tube

braid

•

push back the braid and press it between the two brass disks to
achieve a full 360° grounding; the fold between the disks should have
the same diameter as the brass disks

•

secure the braid with a shielding tube

•

insert the wires into the transmitter housing through the gland.

•

tighten the nut

•

connect the wires into the screw terminals and fasten a cable tie
around the wires

transmitter housing

cable tie

gland

brass disks

rubber ring

nut

Advertising