5 central status indication, 5 central status indication -9, Operating and installation instructions cona – ARI Armaturen CONA control EN User Manual

Page 9: Control 4.5 central status indication

Advertising
background image

Rev. 0040807014 1614

Page 2-9

Operating and Installation Instructions

CONA

®

-control

4.5 Central status indication

Fig. 6

No.

Designation

1

Reset button for resetting stored
fault indications
< 2 s: Resets the corresponding

steam trap

> 2 s: Resets all steam traps

2

Power LED per indication card

3

Fault indications for the
corresponding steam trap
(refer to "4.3 Indications on the
CONA®-control system")

4

Indication card
Indicates the operating states of up
to 30 steam traps

5

AS-i / PROFIBUS gateway

6

Power supply

Advertising