4 dome control from vi-k2/vi-k3, 5 dome control from dvr, Vi-k2/vi-k3 universal keyboard – Videoswitch Vi-K3 User Manual

Page 9

Advertising
background image

Vi-K2/Vi-K3 Universal

Keyboard

Vi-K2 Universal Keyboard User Manual

7

1.1.4

Dome Control from Vi-K2/Vi-K3

Up to 16 domes may be directly connected to the Vi-K2/Vi-K3. The appropriate protocol(s) must be set in the
Vi-K2/Vi-K3. Dome control may be via RS485, RS232 or 20mA loop.

• The Vi-K2/Vi-K3 has two dome outputs “DOMES1” and “DOMES-2”.
• A particular Vi-K2/Vi-K3 can be connected to a maximum of two different types of dome; all of one

type must be connected to the “

DOMES-1” output, and all of the other type of dome must be

connected to the “

DOMES-2” output.

• Each camera (up to 256) must be assigned to use one or other of these outputs (the factory default

assigns all cameras assigned to “

DOMES-1 output).

• Each of the two dome outputs is assigned a dome protocol.
• The domes may be either daisy-chained. In this case, turn the termination off on all domes except

the last in the daisy chain, which should have its termination set on.

• The dome may be connected in “star” mode by means of a RS485 “star expander” (our product

code “VX Hub”). In this case, all domes should have their termination on.

• Each dome must be set up with an address that corresponds with the camera input to which it is

connected (i.e. addresses 1, 2, 3 etc for domes on camera inputs 1, 2, 3 etc)

1.1.5

Dome Control from DVR

If the DVR, or multiple DVRs, have dome control built in, the domes may be connected to the DVR(s) and
the Vi-K2/Vi-K3 used as slave to control everything. The Vi-K2/Vi-K3 protocol must be set to SLAVE (i.e.
number 1). Up to 16 Vi-series DVRs may be linked to provide control of up to 256 dome cameras. Dome
control may be via RS485, RS232, 20mA loop or “up-the-coax” as supported by the DVR(s).

Advertising
This manual is related to the following products: