ELCO

Shrink fit unit Start.2

27/04/2010

Page 10/19

5 – OPERATING

5.1

Principle of functioning

The shrinking (or unshrinking) principle consists in heating an attachment (H1) in order

to expand a chuck bore (H2) and to insert (or remove) the tool’s shank (K1), then

cooling the whole of it in order to get an almost cast solid structure. The heating is

realized by the induction technique. Electromagnetic fields created by induction

generate Foucault currents around the attachment, making it going up to a high

temperature in a few seconds. Because of a very quick warming, only the attachment is

hot, the tool remains at room temperature.

The shrink fit unit needs tools shanks at least equal to h6 quality wise.

5.2

Switching the unit on

Switch the unit on, using the main switch (A6) and bring it to position 1.