ELCO

Shrink fit unit Start.2

27/04/2010

Page 16/19

light « induction »

Switched off : no power, the inductor is not heating

fixed :

The inductor heats the attachment (see §2 safety)

flashing :

« default »

Check that the tool holder is made of material compatible

with the shrink fit unit

light « cooling »

Switched off : cooling is not operating, or was stopped automatically after having

operated for 15 minutes

fixed :

cooling is operating since less than 2 minutes ; it is not possible to

stop it

flashing :

cooling is operating since more than 2 minutes ; it is possible to

stop it

All the lights are flashing : it is a problem between the

generator and the remote control

Switch the unit off, check the connection of the sub-D plug

and if the screws are well tightened.

For any other dysfunction not mentioned in this document, please contact the

manufacturer’s after-sales service.


In any case, NEVER OPEN THE UNIT without being sure that the unit is switched

off (disconnected from electrical power) : DANGEROUS VOLTAGE.