Shrink fit unit Start.2

27/04/2010

Page 12/19

In case of dysfunction, the induction stops itself automatically after the heating period,

and the unit becomes then out of order for 30 seconds ; Do not switch off the unit or do

not unplug the electric network during this time.

Never restart a heating cycle after an induction cut without a complete cooling of the

tool holder.

Never restart a heating cycle after having depressed the induction button without a

complete cooling of the tool holder.

If you do not respect these instructions, this could destroy the tool holder

completely and damages seriously the unit.

5.6

Shrinking modus operandi

In order to avoid burns and cuts, all the handlings must be done with Kevlar gloves

supplied with the unit.

1- After having beforehand set the appropriate chuck holder (A3) and the inductor stop

(A2), put the shrinking tool holder (H1) into the chuck holder. Make sure that the tool

holder is clean, especially the boring (H2) which will receive the tool shank, and free

of any liquid, especially cutting oil.

2- Take the inductor handle (A4) possibly with both hands and bring the inductor (A1)

down until the top of the attachment (H3) contacts the inductor stop (A2)

3- Take the tool for shrinking (K1) with one hand and bring it to the end of the boring

(H2)

4- Press the induction button (A5) (yellow) with the other hand (A4), until you can

introduce the tool into the boring. During that operation, the yellow light (A10) lights

on. As soon as the tool goes down, release immediately the induction button.

5- Bring the inductor back up with the handle

In case of disorder, the induction will switch off automatically. Cool completely the tool

holder and check that the diameter of the tool shank and the attachment match and

check also the position of the selector before repeating the operation.