6.2

Dysfunctions

The main dysfunctions are indicated by position lights :

Light “Status of the shrink fit unit” :

Switched off : The shrink fit unit is switched off

Check that the main switch (A6) is in position 1

Check that the unit is connected to the electric network and

is receiving power

fixed :

The shrink fit unit is switched on

flashing :

There is a default of voltage, at least one phase is not receiving

power

Check the connection of the socket

Check the fuses of the electric network

Light « Blocking of the shrink fit unit”

fixed :

The maximum time allowed for heating or the maximum

temperature of the tool holder has been reached :

The unit is unusable for 30 seconds

Cooling completely the tool holder before any further

attempt.

light « default »

fixed :

The electronic card is overheating

flashing :

The inductor is overheating

Switch the unit off (main switch (A6) on position “0”) for 60

minutes.

This default may be due to intensive use or misuse of the shrink fit unit (use not

in compliance with the instructions).

Fast flashing : The heating cycles are too close (normal use is one cycle every

30 seconds)