Section 2. Installation
9
CLOSING THE UNIT
If the Entry Access Guide or the Exit Access Guide has been opened, close the access guide as
described below:
1. Push to close the access guide (Entry Access Guide or Exit Access Guide) to its normal
operating position (as show in Figure 2-5).
2. If the printer cover is open on the Entry Access Guide, first close the printer cover and then
close the access guide as described in step 1 above.
3. Push down on the tab of the access guide (as shown in Figure 2-5). If the tab was not latched,
a “click” sound will be heard as feedback to indicate the access guide is securely closed.
4. The LED indicator will flash if the access guide is improperly closed (see Table 2-4).
Note
Improperly closed access guides can affect MICR reading and image quality.
Figure 2-5. Closing the Unit
CABLE CONNECTIONS
The cable connections are shown in Figure 2-6.