A rising pattern for bit size is shown in Figure 4-7. The maximum limit of bit size for new
(Unused) cards is exceeded at R14 and again at R25. Technical personnel should be notified in
both instances as both limits are exceeded for new cards. At R27 the card exceeds the maximum
for used (Returned) cards. The operator should graph and print this trend.