InSpec 9000 Encoded Card Tester

66


TRACK 2

Parameter

ISO Term

New Card Limit

Used Card Limit


Signal Amplitude*

Ui

136%

≥ Ui ≥ 64% 136% ≥Ui ≥ 52%

Average Bit Density

Ba

± 5%

± 5%

Flux Transition Spacing Variation

Bin

± 5%

± 15%

Subinterval Spacing Variation

Sin

± 7%

± 20%

Adjacent Bit Cell Variation

Bin+1

± 8%

± 15%

Adjacent Subinterval Variation

Sin+1

± 10%

± 30%

Start Sentinel Position

0.293" ± 0.020" (7.44 ± 0.50 mm) per ISO 7811-4


* as a percent of Reference Signal Amplitude

TRACK

3


Parameter

ISO Term

New Card Limit

Used Card Limit


Signal Amplitude*

Ui

136%

≥ Ui ≥ 64%

136%

≥Ui ≥ 52%

Average Bit Density

Ba

± 8%

± 8%

Flux Transition Spacing Variation

Bin

± 8%

± 15%

Subinterval Spacing Variation

Sin

± 10%

± 20%

Adjacent Bit Cell Variation

Bin+1

± 8%

± 15%

Adjacent Subinterval Variation

Sin+1

± 10%

± 30%

Start Sentinel Position

0.293" ± 0.040" (7.44 ± 1.00 mm)
per ISO 7811-5


* as a percent of Reference Signal Amplitude

Note

The ISO Standard uses the terminology of Unused Encoded cards
and Returned Cards for New cards and Used cards respectively.


An ISO committee has defined requirements for High Coercivity Magnetic Stripes. The
document is undergoing a final public review before publication as a Standard. The basis of this
pending standard is for reader compatibility with the "low coercivity" Standard (ISO/IEC 7811-
2). Since the Encoded Card Tester only measures previously encoded cards and does not
perform any encoding (recording) functions, the Tester is transparent to whether the card has a
High Coercivity or a Low Coercivity magnetic stripe.