Aalborg DFM Digital User Manual

Page 43

Advertising
background image

39

Note: Address 00 is reserved for global addressing. Do not assign
global address for any device. When command with global address is
sent, all devices on the RS-485 bus execute the command, but do not
reply with acknowledge message.

The global address can be used to change RS-485 address for a particular
device with unknown address:

1.

Make sure only one device (which address has to be changed) is
connected to the RS-485 network.

2.

Type the memory write command with global address:
!00,MW,7,XX[CR]

where XX, the new hexadecimal address can be [01 - FF].
After assigning the new address a device will accept commands with
the new address.

Note: Do not assign the same RS-485 address for two or more
devices on the same RS-485 bus. If two or more devices with the
same address are connected to the one RS-485 network, the bus will
be corrupted and communication errors will occur.

,

,