• Use the Device Configuration Utility to change settings in the camera and

other PakBus devices. Datalogger parameters can also be incorporated
into the datalogger program or changed with a keyboard display.

• Verify that the lens cable is properly seated, as the connector may

inadvertently become unplugged during handling or installation.

Device Configuration Utility is included in LoggerNet, PC400,
and as a free download.

NOTE

Always place the Power Switch in the Auto Position.

3. Camera Hardware Description

3.1 Terminal Block Connections

Only shielded cable should be used for connections to the
terminal block.

NOTE

Gnd Power

Ground

+12VDC

9-15VDC Power, 250 mA

Ext.

External Trigger Input, 5.0 Volt Logic Signal, 15Volts Max

RS-485A RS-485

communication

RS-485B RS-485

communication

Shield

The shield (drain wire) needs to be connected to this terminal

FIGURE 2. Terminal Block Position and Layout